Global warming potential (GWP) compares a gas's warming with carbon dioxide's, so gases can be summed as CO2 equivalent (CO2e). AASB S2 expects 100-year values from the IPCC's Sixth Assessment Report (AR6) when you convert gases yourself. Factors already in CO2e, like the NGA Factors, need no recalculation. For periods beginning in 2027 or later, NGER-covered emissions may use AR5.
Key takeaways
- AASB S2 paragraph AusB22.1 fixes "the latest" IPCC assessment as the Sixth Assessment Report (AR6).
- Factors already in CO2e, like the AR5-based NGA Factors, need no recalculation under paragraph B22.
- Australia uses three GWP sets at once: AR4 for the HFC phase-down, AR5 for NGER and the national inventory, and AR6 as the AASB S2 default.
- For annual periods beginning on or after 1 January 2027, the amended AASB S2 lets the NGER-covered part of an entity keep AR5 values. Earlier adoption is allowed and must be disclosed.
- In an illustrative example, 20 kg of leaked HFC-134a is 26.0 t CO2e at AR5 but 30.5 t at AR6, about 17% more.
What is global warming potential?
AASB S2 defines global warming potential as "a factor describing the radiative forcing impact (degree of harm to the atmosphere) of one unit of a given greenhouse gas relative to one unit of CO2." The Clean Energy Regulator puts it more plainly: "The heat-trapping ability of a gas measured against carbon dioxide is its GWP." Reporting uses a 100-year horizon.
The GWP turns a mass of gas into its CO2 equivalent, written CO2e or CO2-e. AASB S2 Climate-related Disclosures, the climate standard in the Australian Sustainability Reporting Standards (ASRS), defines CO2e as "the universal unit of measurement to indicate the global warming potential of each greenhouse gas". Paragraph B20 then requires an entity to "aggregate the seven constituent greenhouse gases into CO2 equivalent values". These are the seven gases listed in the Kyoto Protocol, which include carbon dioxide, methane, nitrous oxide and the hydrofluorocarbons (HFCs) used as refrigerants.
The arithmetic is simple. Tonnes of CO2e equal tonnes of gas multiplied by its GWP. As a result, the hard part of the work is choosing which GWP numbers to multiply by, and saying so.
What does a GWP of 1 mean?
Carbon dioxide has a GWP of 1 by definition. So a gas with a GWP of 1 causes the same warming as the same mass of carbon dioxide. A gas with a GWP of 1,300 causes 1,300 times that warming per tonne emitted. That is why a small refrigerant leak can matter more than its weight suggests.
Is a high GWP good or bad?
Neither, because the number is a weighting rather than a verdict. A high GWP means more warming per tonne, so a leak of that gas carries more weight in the inventory. In other words, it tells you where small quantities need careful measurement.
Why are there different GWP values?
The Intergovernmental Panel on Climate Change (IPCC) revises GWP values in each assessment report as the science improves. Values from the Fourth (AR4, 2007), Fifth (AR5, 2014) and Sixth (AR6) Assessment Reports are all still in use. According to the GHG Protocol, AR6 values are the most recent, but older ones "are sometimes used".
The table below sets out 100-year GWP values for the gases most Australian inventories meet. Each column header names where Australia uses that set.
Carbon dioxide
- AR4 (HFC phase-down): 1
- AR5 (NGER, NGA Factors, national inventory): 1
- AR6 (AASB S2 default): 1
Methane
- AR4 (HFC phase-down): 25
- AR5 (NGER, NGA Factors, national inventory): 28
- AR6 (AASB S2 default): 27.0 (non-fossil), 29.8 (fossil)
Nitrous oxide
- AR4 (HFC phase-down): 298
- AR5 (NGER, NGA Factors, national inventory): 265
- AR6 (AASB S2 default): 273
HFC-32 (R-32)
- AR4 (HFC phase-down): 675
- AR5 (NGER, NGA Factors, national inventory): 677
- AR6 (AASB S2 default): 771
HFC-134a (R-134a)
- AR4 (HFC phase-down): 1,430
- AR5 (NGER, NGA Factors, national inventory): 1,300
- AR6 (AASB S2 default): 1,526
Sources: AR4 HFC values from DCCEEW's refrigerant page, and AR4 methane and nitrous oxide from the Clean Energy Regulator; AR5 from NGA Factors 2026, Appendix 2, which match NGER regulation 2.02; AR6 from IPCC AR6 Working Group I, Table 7.15. The AR5 values Australia uses give one figure for all methane. AR6 values are the IPCC's central estimates, and the GHG Protocol's table rounds HFC-134a to 1,530.
Where does Australia use each set?
Australia runs all three sets side by side, each for its own instrument:
- AR4. The Department of Climate Change, Energy, the Environment and Water (DCCEEW) publishes AR4 values for HFCs regulated under the Ozone Protection and Synthetic Greenhouse Gas Management Act 1989. It says the Act "will continue to use AR4 values" to keep phase-down baselines consistent.
- AR5. The National Greenhouse and Energy Reporting (NGER) scheme has required AR5 values since the 2020-21 reporting year. DCCEEW's National Greenhouse Accounts (NGA) Factors and Australia's Paris Agreement inventory also use AR5.
- AR6. AASB S2 paragraph AusB22.1 makes AR6 the default for AASB S2 reporting.
On methane, AR6 splits fossil and non-fossil values. The GHG Protocol says to use the fossil value for fugitive emissions from fossil fuel sources, and the non-fossil value for combustion emissions.
Which GWP values does AASB S2 require?
If you convert gases into CO2e yourself, AASB S2 requires 100-year GWP values from the latest IPCC assessment, which paragraph AusB22.1 defines as AR6. That covers direct measurement (paragraph B21) and emission factors not already in CO2e (paragraph B22). However, if a factor is already in CO2e, B22 says you are not required to recalculate it.
AusB22.1 is an Australian addition to the international wording. It reads: "the latest Intergovernmental Panel on Climate Change assessment available at the reporting date means the Panel's Sixth Assessment Report." Because the paragraph names AR6, the default stays put until the standard itself changes. For the rest of the standard's structure, see the AASB S2 hub.
There is some history here. The AASB's exposure draft, ED SR1, proposed AR5, the set NGER uses. The final standard did not take that route. Instead, its Basis for Conclusions notes that the NGA Factors "have already converted greenhouse gases into CO2 equivalent values using the GWP values from IPCC AR5, which is consistent with the Paris Agreement." The Basis for Conclusions accompanies the standard but is not part of it.
Do you need to convert NGA factors to AR6?
No. The NGA Factors are, in DCCEEW's words, "generally expressed on a carbon dioxide equivalent (CO2-e) basis" using AR5 values. So paragraph B22 applies, and the AASB named these factors in its own reasoning. For the basics, see what an emission factor is.
Which factor set and which edition to use is a separate question, covered in the guide to AASB S2 emission factors. Note also that DCCEEW says the NGA workbook is "not published for the purposes of reporting" under NGER.
When do you need AR6 values?
You need AR6 values when you hold a mass of gas and convert it yourself. For a service business, a typical example is refrigerant top-ups recorded in air conditioning service records. A leak like that is a Scope 1 emission, meaning a direct emission from equipment the entity controls. By contrast, fuel figures and Scope 2 figures (emissions from the electricity you buy) come from CO2e factors, so they are unaffected.
Be careful with the reference tables to hand. The NGA workbook prints AR5 refrigerant values, while DCCEEW's refrigerant page prints AR4. Neither is the AASB S2 default for a gas you convert yourself. Whether you call the calculation direct measurement or a factor not in CO2e, B21 and B22 lead to the same AR6 answer.
Here is what the choice does to one leak. The 20 kg is invented for the example.
Refrigerant page value, AR4
- GWP: 1,430
- t CO2e (kg x GWP / 1,000): 28.6
NGA Factors 2026 value, AR5
- GWP: 1,300
- t CO2e (kg x GWP / 1,000): 26.0
AASB S2 default, AR6
- GWP: 1,526
- t CO2e (kg x GWP / 1,000): 30.5
The AR6 figure is 17.4% higher than the AR5 one. On a small inventory, that is a visible difference for the same leak.