A carbon accounting template is a spreadsheet that converts activity data into tonnes of CO2-e with emission factors and records the source of every number. Under AASB S2 it must produce Scope 1 and 2, then Scope 3 from year two. A spreadsheet can carry year one. It stops being enough when someone else cannot trace each number back.
Key takeaways
- AASB S2 paragraph 29(a)(iii) requires disclosure of the measurement approach, inputs and assumptions, the reasons for them, and any changes.
- AASB S2 prescribes no emission factors. Instead, it asks for factors that best represent the activity, and the AASB names the NGA Factors as one Australian source.
- In a Group 2 entity's first year, Scope 3 and comparatives are not required, and the review takes in Scope 1 and 2 emissions.
- According to ASIC, sustainability records must be kept for seven years after the report is completed.
- Under ASSA 5010 as it stands, Group 2 reports are audited rather than reviewed from the fourth year. Treasury's 2026 consultation asked whether to keep limited assurance instead.
What is a carbon accounting template?
A carbon accounting template is a workbook with one row per emissions source, each multiplying a quantity of activity by an emission factor. It mechanises the five calculation steps in the GHG Protocol Corporate Standard, which AASB S2 uses for measurement. The Protocol's own tools are optional, and a company may substitute methods consistent with its approaches.
Four terms do most of the work. Activity data is the quantity of something that causes emissions, such as kilowatt hours of electricity, kilolitres of diesel or kilograms of refrigerant. An emission factor is the emissions per unit of that activity. CO2-e, or carbon dioxide equivalent, expresses each greenhouse gas as the amount of carbon dioxide with the same warming effect, so different gases can be added together.
The results are then sorted by scope. Scope 1 covers direct emissions from sources the entity owns or controls, such as its vehicles and gas boilers. Indirect emissions from the electricity it buys are Scope 2, and every other indirect emission in its value chain, from suppliers to customers, is Scope 3.
The Corporate Standard sets out five steps: identify the sources, select a calculation approach, collect activity data and choose emission factors, apply calculation tools, and roll the data up to corporate level. It groups direct sources into stationary combustion, mobile combustion, process and fugitive emissions. For most small to medium-sized companies, it says, Scope 1 "will be calculated based on the purchased quantities of commercial fuels". Scope 2, it adds, "will primarily be calculated from metered electricity consumption". For a services business, that usually means fuel cards, gas bills and electricity bills.
This is an organisation's emissions workbook, not FullCAM, the land sector model that also appears in searches for the term.
What does AASB S2 need your template to produce?
AASB S2 paragraph 29(a) asks for absolute gross Scope 1, 2 and 3 emissions in tonnes of CO2-e, measured under the GHG Protocol Corporate Standard (2004). Scope 1 and 2 are split between the consolidated accounting group and other investees. Scope 2 is location-based, and the approach, inputs and assumptions are disclosed, with any changes and the reasons.
AASB S2 is the climate standard within the Australian Sustainability Reporting Standards (ASRS), and each phrase in paragraph 29(a) shapes a column or a tab. "Gross" means before any removals. The AASB's educational material says the entity measures emissions "without taking into consideration any removal efforts (for example, through the use of carbon credits)". So carbon credits never reduce a row. The disclosure also covers emissions "generated during the reporting period", which is why every row carries its dates.
The split in paragraph 29(a)(iv) separates "the consolidated accounting group" (the parent and its consolidated subsidiaries) from "other investees" (associates, joint ventures and unconsolidated subsidiaries). Paragraph B27 requires the equity share or control approach, with the reason for the choice disclosed. Paragraph Aus20.1 requires the disclosures to cover the same reporting entity as the financial statements, unless the law permits otherwise, so the template's entity list should match the consolidation.
Under paragraph B30, the location-based figure is mandatory. The NGA Factors calculate it with the average factor for the state grid where the electricity is used. Contractual instruments, such as green power agreements, are disclosed only if they exist and help users understand the figure.
The AASB's material states that "AASB S2 does not reference the GHG Protocol Corporate Standard's requirements beyond measurement". So this template records CO2-e, the disclosure's own unit, rather than one column per gas.
What columns does a carbon accounting template need?
A carbon accounting template needs one row per source, site and period, and sixteen columns. They run from where and when, through what was used and its evidence, to the factor, the result and the review. Four small tabs sit beside the rows, and each column below names the paragraph or source that asks for it.
We built this template from AASB S2, the NGA Factors and ASIC's guidance on sustainability records. It is not copied from any published template. The three tables below are one record, so lay them side by side as the columns of a single sheet.
Which row is it? Columns 1 to 5
1. Row ID
- What to record: A unique reference that never changes
- Why it is there: The Corporate Standard asks for results "based on a clear audit trail", and an ID lets anyone follow one row
2. Period from, period to
- What to record: The dates the bill or meter read covers
- Why it is there: AASB S2 counts emissions "generated during the reporting period". Bills rarely match the financial year, so flag any row you apportion
3. Legal entity
- What to record: The company in the group
- Why it is there: Paragraph Aus20.1, because the report covers the same entity as the financial statements
4. Site
- What to record: Address or meter number
- Why it is there: Lets you roll up by site. In addition, the state decides the electricity factor
5. Group or investee
- What to record: Consolidated accounting group, or other investee
- Why it is there: Paragraph 29(a)(iv) splits Scope 1 and 2 this way
What was used? Columns 6 to 11
6. Scope
- What to record: 1 or 2, and 3 from year two
- Why it is there: Paragraph 29(a)(i)
7. Source category
- What to record: Stationary, mobile, fugitive, process, or purchased electricity
- Why it is there: The Corporate Standard's source categories
8. Activity
- What to record: Grid electricity, natural gas, fleet diesel, refrigerant top-up
- Why it is there: Paragraph B29, because the factor must "best represent" this activity
9. Quantity and unit
- What to record: kWh, kL, GJ or kg
- Why it is there: The factor's unit decides the conversion, so the two must match
10. Actual or estimated
- What to record: Meter read or invoice, or the basis of the estimate
- Why it is there: Paragraph 29(a)(iii) asks for assumptions. ASIC's Report 839 also asks for clear disclosure of judgements, assumptions and areas of measurement uncertainty
11. Evidence reference
- What to record: Invoice number, fuel card statement, file location
- Why it is there: RG 280.50 describes sustainability records as the documents and working papers explaining the methods, assumptions and evidence behind the report
How was it converted? Columns 12 to 16
12. Emission factor and unit
- What to record: For example, 0.74 kg CO2-e per kWh
- Why it is there: Paragraph B26(c) asks for the emission factors used
13. Factor source, edition and table
- What to record: For example, "NGA Factors 2026, Table 1, Victoria"
- Why it is there: Factors are revised every year, so the edition matters
14. Energy content factor
- What to record: Fuels only, for example 38.6 GJ per kL of diesel
- Why it is there: The NGA method for fuels converts volume to energy first
15. Tonnes CO2-e
- What to record: A formula, never a typed number
- Why it is there: The NGA calculation, which is quantity times factor, divided by 1,000
16. Prepared by, reviewed by, date
- What to record: Names and dates
- Why it is there: The Corporate Standard's quality guidance begins with "an inventory quality team"
What tabs sit beside the rows?
- Boundary. The entities, their ownership and control, the approach chosen (equity share or control) and why, as paragraph B27 asks.
- Factor register. Every factor used, its edition and table, and the date it was last checked.
- Method and change log. Each change to the approach, inputs or assumptions, with its reason, because paragraph 29(a)(iii)(3) asks for exactly that.
- Summary. Scope 1 and Scope 2 (location-based), each split between the consolidated accounting group and other investees.
In year two, add a Scope 3 tab. Its rows record the category (1 to 15), whether the input comes from specific activities in the value chain, and whether it was verified. That is because paragraph B56 asks for the extent of each.
How do you calculate emissions in the template?
Every GHG emissions calculation template runs on one formula from the NGA Factors: quantity times emission factor, divided by 1,000 when the factor is in kilograms, to give tonnes of CO2-e. Fuels add a step, because the quantity is first converted to energy with an energy content factor. The two worked examples below show both cases.
According to DCCEEW's National Greenhouse Accounts (NGA) Factors 2026, the location-based Scope 2 factor for grid electricity in Victoria is 0.74 kg CO2-e per kWh. Both examples are illustrations built from Tables 1 and 9 of that edition, not a customer's figures.
Example 1, electricity (illustrative). A Victorian office uses 250,000 kWh of grid electricity in the year. Its location-based Scope 2 emissions are 250,000 x 0.74 / 1,000, which is 185 tonnes CO2-e. The NGA formula for electricity also adds a Scope 3 factor (0.11 for Victoria), which this example leaves out so the figure stays Scope 2.
Example 2, diesel (illustrative). A fleet of cars and light commercial vehicles built from 2004 onwards uses 50 kL of diesel. Table 9 gives an energy content of 38.6 GJ per kL and a combined Scope 1 factor of 70.41 kg CO2-e per GJ. So the Scope 1 emissions are 50 x 38.6 x 70.41 / 1,000, or about 136 tonnes CO2-e. Vehicles built before 2004 use different methane and nitrous oxide values, which is why the activity column needs that detail.
The unit column matters too: enter the diesel in litres instead of kilolitres and the result is a thousand times too high. If factors are new to you, the guide to how emission factors work explains the idea in more depth.
.png)
.png)
.png)
.webp)