Learn: Carbon accounting

Scope 1, 2 and 3 emissions examples by industry

Scope 1 emissions come from sources a business owns or controls, such as fuel in its own vehicles and refrigerant leaking from air conditioning. The electricity, heating or cooling it buys is Scope 2. Scope 3 is everything else in its value chain. So the examples that matter vary by industry, from an office's flights to a bank's lending.

Key takeaways

  • AASB S2 Climate-related Disclosures requires all three scopes, Scope 3 included, even though the Greenhouse Gas (GHG) Protocol's Corporate Standard leaves Scope 3 optional.
  • An office-based business can still have Scope 1 emissions, because the GHG Protocol lists refrigerant leaks from air conditioning for the service sector.
  • According to CDP's global 2021 data, category 15 (investments), where financed emissions sit, made up over 99% of the emissions reported by 377 financial services companies.
  • A reporter considers all 15 Scope 3 categories and discloses which it includes, and the AASB's own example shows that not every category applies.
  • For Group 2, Scope 3 is not required in the first year, which starts 1 July 2026 for a 30 June year end, and it comes in with limited assurance the year after.

What are Scope 1, 2 and 3 emissions?

AASB S2 defines Scope 1 as direct emissions from sources an entity owns or controls. Scope 2 is indirect emissions from generating the electricity, steam, heating or cooling it buys and uses. Scope 3 is all other indirect emissions in its value chain, both upstream among its suppliers and downstream among its customers.

AASB S2 Climate-related Disclosures is the climate standard within the Australian Sustainability Reporting Standards (ASRS). Paragraph 29(a) asks for all three scopes, measured under the GHG Protocol Corporate Standard (2004) unless a jurisdictional authority requires another method. That standard leaves Scope 3 optional. However, paragraph B23 says the entity "is required to disclose Scope 3 greenhouse gas emissions" all the same.

ASIC puts Scope 3 another way: "the Scope 1 and 2 greenhouse gas emissions of external entities that fall within your entity's inventory boundary". So one company's Scope 1 or 2 is part of another company's Scope 3. Our page on what the three scopes are covers the definitions in more depth.

Scope 1, 2 and 3 emissions examples by industry

The eight industries below run from professional services to food, and they leave out asset-heavy sectors such as mining and energy. Each entry lists Scope 1 and Scope 2 examples, the Scope 3 categories most likely to matter, and one question to settle. Every example rests on a primary source, named in the entry.

The order is not a ranking. Category numbers refer to the 15 Scope 3 categories in the GHG Protocol's Scope 3 Standard. "Most likely to matter" is a prompt rather than a finding, because whether a category applies is decided entity by entity.

Three entries carry worked numbers. They use an emission factor, which is the figure that converts an activity, such as a litre of diesel or a kilowatt hour of electricity, into emissions. Results are in tonnes of carbon dioxide equivalent (CO2-e), a common unit that weights each greenhouse gas by its warming effect. The factors come from DCCEEW's National Greenhouse Accounts (NGA) Factors 2026. Where we have redone ASIC's arithmetic with them, the entry says so, and the numbers are illustrative.

1. Professional services (legal, accounting and consulting)

Scope 1 examples: Refrigerant leaking from office air conditioning, which is a fugitive emission: a greenhouse gas that escapes rather than being burned. Fuel in any vehicles the firm owns or controls, and gas burned for heating, also count.

Scope 2 examples: Electricity bought for offices, plus any purchased heat or steam.

Scope 3 categories most likely to matter: Category 1 (purchased goods and services) covers what the Scope 3 Standard lists as "office supplies, office furniture, computers, telephones, travel services, IT support, outsourced administrative functions, consulting services, and janitorial and landscaping services". Business travel (category 6) includes ASIC's example of "flights for employees to attend inter-state meetings". Employee commuting (category 7) may also include working from home, which the Scope 3 Standard makes optional. Category 5 (waste generated in operations) covers landfill waste from the office.

The question to settle: Where a firm leases its office, the Scope 3 Standard says whether the lessee counts that space's emissions as Scope 1, 2 or 3 "depends on the organizational boundary approach and the type of leasing arrangement". So electricity in a leased office is not automatically Scope 2, and the answer follows from your reporting boundary. According to ASIC, a business run through a partnership is not directly caught by the reporting requirements, so this entry is for incorporated firms.

Source: GHG Protocol Corporate Standard, Appendix D; Scope 3 Standard, pages 38, 46 and 125; ASIC Module 6, Unit 4.

2. Software and technology

Scope 1 examples: The same sources as any office business: refrigerant from air conditioning, and fuel in vehicles or heating the company owns or controls. The GHG Protocol's row for office-based organisations lists all three kinds of source.

Scope 2 examples: Electricity for offices the company controls.

Scope 3 categories most likely to matter: Category 1 covers bought-in services, which the Scope 3 Standard says include "IT support" and "outsourced administrative functions". Computers fall in category 1 or category 2 (capital goods), and the Standard says companies "should follow their own financial accounting procedures" to decide which. Business travel and commuting (categories 6 and 7) apply as they would for any office. A company that sells software tests category 11 (use of sold products) too: the Scope 3 Standard's examples of products that use energy directly include "data centers, web-based software". For category 12 (end-of-life treatment of sold products), the AASB's own example says it is likely "not relevant for a services company, such as a digital advertising company that does not sell any products".

The question to settle: Hosted infrastructure. Among purchases, the Scope 3 Standard names IT support and computers but not cloud or data centre services, so how bought-in hosting is classified is a judgement to record, with the reasoning. A company that also sells physical products would look at category 12 again, since the AASB's example of where it is relevant is a product seller.

Source: GHG Protocol Corporate Standard, Appendix D; Scope 3 Standard, pages 38, 39 and 48; AASB educational material (August 2025), Question 4.

3. Banking, insurance and asset management

Scope 1 examples: Refrigerant leaks, and any gas or vehicle fuel, at offices and branches the entity controls.

Scope 2 examples: Electricity for those offices and branches.

Scope 3 categories most likely to matter: Category 15 (investments), which holds financed emissions: the share of a borrower's or investee's emissions attributed to the entity's loans and investments. AASB S2 paragraph 29(a)(vi)(2) asks for more on financed emissions where activities include "asset management, commercial banking or insurance". Under paragraphs B62 and B63, that includes gross financed emissions "disaggregated by Scope 1, Scope 2 and Scope 3 greenhouse gas emissions for each industry by asset class". According to CDP, category 15 made up over 99% of the emissions reported by 377 financial services companies in 2021, although only 37% of them reported it as relevant and calculated. CDP also says portfolio emissions are "on average over 700 times larger than direct emissions".

The question to settle: How far category 15 reaches. For annual periods beginning on or after 1 January 2027, the compiled AASB S2 lets an entity limit category 15 to financed emissions only (paragraph 29A), and earlier application is permitted. In the first year, the Scope 3 relief also covers the financed emissions disclosures (paragraph C4(b)). The AASB's educational material explains why this matters: a commercial bank's transition risk, the risk from the move to a lower-carbon economy, "might primarily arise" from emissions in its loan portfolio.

Source: AASB S2 paragraphs 29(a)(vi), 29A, B62, B63 and C4; AASB educational material, page 6; CDP technical note, section 2.8.

4. Property and real estate (owners and landlords)

Scope 1 examples: Gas burned for heating or hot water, and refrigerant leaking from air conditioning, in buildings the entity controls.

Scope 2 examples: Electricity for those buildings, including common areas the owner runs.

Scope 3 categories most likely to matter: Category 13 (downstream leased assets), for which ASIC's example is "energy (such as heating, cooling and electricity) use from a building leased out by an entity". CDP says building owners should consider category 13 relevant, and that category 1 "may also be relevant to account for facilities management and contractors". In CDP's 2021 data, category 13 was 27% of the Scope 3 emissions reported by 156 real estate companies. CDP also cites the UK Green Building Council's estimate that Scope 3 contributes "over 85%" of a commercial real estate company's footprint on average. In addition, category 2 can matter, because the Scope 3 Standard lists buildings and facilities as capital goods.

The question to settle: Where a tenant's energy use sits. The Scope 3 Standard applies the same test to a lessor as to a lessee: it depends on the boundary approach and the type of lease. As a result, the same building can sit in the owner's Scope 1 and 2, or in its category 13.

Source: ASIC Module 6, Unit 4; CDP technical note, section 2.13; Scope 3 Standard, pages 39 and 125.

5. Retail

Scope 1 examples: Refrigerant leaking from refrigeration and air conditioning in stores, which the GHG Protocol lists as a fugitive source. Fuel in delivery vehicles the retailer owns or controls is also Scope 1.

Scope 2 examples: Electricity for stores, warehouses and offices.

Scope 3 categories most likely to matter: Category 1, which the Scope 3 Standard says includes "final goods purchased for resale (for retail and distribution companies only)". Downstream transportation and distribution (category 9) has ASIC's example of "transporting food products to an entity's customers". For use of sold products (category 11), ASIC's example is "customers using electrical appliances sold by a retailer". Category 12 has ASIC's example of "incinerating product packaging". Franchises (category 14) apply where the retailer franchises its stores.

The question to settle: Which products have use-phase emissions at all. ASIC's category 11 example is appliances that use electricity, so a retailer checks which of its products use energy when customers use them. Then it records the answer, whichever way it falls.

Source: GHG Protocol Corporate Standard, chapter 4; Scope 3 Standard, page 38; ASIC Module 6, Units 2 and 4.

6. Hospitality and clubs

Scope 1 examples: Gas or other fuel burned on site, which ASIC illustrates with "fuel burned in boilers or furnaces". Refrigerant leaking from refrigeration and air conditioning is a second source.

Scope 2 examples: ASIC's worked example is a boutique hotel group using 2,000,000 kWh a year at two Sydney properties and 500,000 kWh at one in Brisbane. On DCCEEW's 2026 location-based factors, which are the average for each state's grid, NSW is 0.60 and Queensland 0.65 kg CO2-e per kWh. That gives 1,200 t plus 325 t, or 1,525 t CO2-e. This is our recalculation, because ASIC used the 2025 factors.

Scope 3 categories most likely to matter: Category 1 for the food, drink and supplies bought. Waste falls in category 5, where ASIC's example includes food scraps. Category 3 (fuel- and energy-related activities) for the electricity's upstream share, since DCCEEW's Scope 3 factors include electricity lost through the grid. For the same hotels, our calculation adds 140 t plus 55 t, or 195 t CO2-e.

The question to settle: Venues run by franchisees. ASIC's example for category 14 (franchises) is "a franchised fast-food outlet". So a franchisor checks which venues sit inside its own boundary and which fall in category 14.

Source: ASIC Module 6, Units 2, 3 and 4; NGA Factors 2026, Table 1.

7. Facilities management and field services

Scope 1 examples: Fuel for the service fleet. In ASIC's worked example, "Facility A has used 20,000 litres of diesel for its fleet of light commercial vehicles." At 38.6 GJ per kilolitre that is 772 GJ, and at 70.41 kg CO2-e per GJ it is 54.36 t CO2-e. DCCEEW's 2026 factors for diesel in cars and light commercial vehicles are the same, so the figure holds.

Scope 2 examples: Electricity for depots, workshops and offices.

Scope 3 categories most likely to matter: Category 1 for the materials, parts and subcontracted services bought. Waste from operations falls in category 5. Category 3 for the diesel's upstream emissions, where DCCEEW's Scope 3 factor is 17.3 kg CO2-e per GJ. On that factor, our calculation adds 13.36 t CO2-e to ASIC's example.

The question to settle: Equipment at a client's site. AASB S2 puts a source in Scope 1 when it is "owned or controlled by an entity". So refrigerant or fuel in equipment the firm services, but the client owns, needs a recorded decision on ownership and control. No standard we read rules on this case directly.

Source: ASIC Module 6, Unit 2; NGA Factors 2026, Table 9; AASB S2 Appendix A.

8. Food and consumer goods

Scope 1 examples: Gas burned for process heat, and refrigerant leaking from refrigeration equipment and refrigerated vehicles the business owns or controls. DCCEEW's indicative annual leakage rate for transport refrigeration is 15.7% of the refrigerant charge.

Scope 2 examples: Electricity for production sites, cold storage and warehouses.

Scope 3 categories most likely to matter: ASIC's own worked example is an entity "that produces packaged food products". It picks category 1 for packaging materials, category 5 for food scraps and category 9 for shipping products to retailers. ASIC also notes "it is likely that only some categories will be relevant to your entity's circumstances rather than all 15 categories".

The question to settle: Category 12, end-of-life treatment of sold products. The AASB's example of where it would likely be relevant is a car maker selling to end consumers. In addition, ASIC's category 12 example is "incinerating product packaging". So a business that sells packaged goods would test category 12 rather than assume it away.

Source: ASIC Module 6, Units 2 and 4; NGA Factors 2026, Table 10; AASB educational material, Question 4.

How do the eight industries compare?

Every industry has some Scope 1 and Scope 2, even the office-based ones. The differences sit mostly in which Scope 3 categories come first.

Professional services

  • Main Scope 1 sources: Air conditioning refrigerant, owned vehicles, gas heating
  • Scope 2: Office electricity
  • Scope 3 categories most likely to matter: 1, 5, 6, 7

Software and technology

  • Main Scope 1 sources: Air conditioning refrigerant, owned vehicles, gas heating
  • Scope 2: Office electricity
  • Scope 3 categories most likely to matter: 1, 2, 6, 7, 11

Banking, insurance and asset management

  • Main Scope 1 sources: Refrigerant, gas and fuel at offices and branches
  • Scope 2: Office and branch electricity
  • Scope 3 categories most likely to matter: 15

Property and real estate

  • Main Scope 1 sources: Gas and refrigerant in controlled buildings
  • Scope 2: Electricity for controlled buildings and common areas
  • Scope 3 categories most likely to matter: 1, 2, 13

Retail

  • Main Scope 1 sources: Refrigeration and air conditioning refrigerant, delivery vehicles
  • Scope 2: Store and warehouse electricity
  • Scope 3 categories most likely to matter: 1, 9, 11, 12, 14

Hospitality and clubs

  • Main Scope 1 sources: Gas or fuel burned on site, refrigerant
  • Scope 2: Venue electricity
  • Scope 3 categories most likely to matter: 1, 3, 5, 14

Facilities management

  • Main Scope 1 sources: Service fleet fuel
  • Scope 2: Depot and office electricity
  • Scope 3 categories most likely to matter: 1, 3, 5

Food and consumer goods

  • Main Scope 1 sources: Process heat from gas, refrigerant including transport
  • Scope 2: Site and cold storage electricity
  • Scope 3 categories most likely to matter: 1, 5, 9, 12

Which Scope 3 categories does AASB S2 make you include?

AASB S2 paragraph B32 says an entity "shall consider" its entire value chain and all 15 Scope 3 categories, then disclose which ones it includes. It does not require all 15 to be measured. The AASB's own example shows the point: end-of-life treatment of sold products is likely not relevant for a services company that sells no products.

So the Scope 3 emissions examples above are a starting point, not a checklist. CDP warns that companies "may end up measuring and reporting emissions in categories which are easy to calculate (e.g., business travel) rather than categories where the bulk of their emissions occur". In CDP's sample of high-impact sectors, from global 2021 data, business travel and commuting were 0.10% and 0.20% of Scope 3 on average, though CDP adds that they "may be relevant for some sectors". Professional services and software were not among the sectors it analysed, and no source we found gives a figure for them.

There is also no prescribed industry list in Australia. IFRS S2 is the international standard AASB S2 is built from, and it points reporters to industry-based guidance. The AASB decided, "as an interim measure", not to require those industry-based disclosures (Basis for Conclusions, BC28).

How do you find the examples in your own business?

Start from records the business already keeps, then map each line to a scope. Fuel logs, refrigerant servicing reports and vehicle receipts point to Scope 1. Electricity bills point to Scope 2. The general ledger shows purchases, travel and freight, which is the starting point for several Scope 3 categories.

For Scope 1 emissions examples, ASIC's module lists the records to gather: "fuel consumption logs, refrigerant servicing reports", heating, ventilation and air conditioning "(HVAC) maintenance logs", and "vehicle usage, mileage, and fuel receipts". For refrigerant, DCCEEW says to "refer to the manufacturer's product specification to determine the type and the charge". Then each activity is multiplied by its factor from the NGA Factors 2026, and our guide to Australian emission factors explains how those are chosen. The Clean Energy Regulator notes that the same factors can be used "to estimate scope 3 emissions".

A common belief is that an office business has no Scope 1 at all. However, the GHG Protocol's own table for office-based organisations lists fugitive emissions, "mainly HFC emissions during use of refrigeration and air-conditioning equipment". The servicing records for the air conditioning are therefore worth finding, even in a business with no vehicles.

Where Trace fits

Trace's carbon accounting software works from the same records. It connects read-only to accounting systems, including Xero, Microsoft Dynamics 365, MYOB, NetSuite and QuickBooks, and maps expenses to emissions categories. It also reads invoices and utility bills, classifying transactions against GHG Protocol categories. Both spend-based methods, which estimate emissions from dollars spent, and activity-based methods, which use quantities such as litres or kilowatt hours, are supported. Deciding which categories are relevant and included stays with the reporter, since paragraph B32 asks the entity to disclose that choice.

When do Group 2 entities have to report each scope?

Group 2 entities report Scope 1 and 2 from their first year, which for a 30 June year end starts 1 July 2026. Under AASB S2's transition relief, Scope 3 is not required in that first year. It comes in from the second year, starting 1 July 2027 for a 30 June year end, with limited assurance.

The assurance timing comes from ASSA 5010, the Auditing and Assurance Standards Board's standard on the timeline for audits and reviews. For Group 2, year one covers financial years starting 1 July 2026 to 30 June 2027, and year two those starting 1 July 2027 to 30 June 2028. Scope 1 and 2 have limited assurance in years one to three. Scope 3 has none in year one, limited assurance in years two and three, and reasonable assurance, the higher level, from year four. AASB S2 paragraph C5 also lets the relief carry into the comparative figures.

ASIC's review of the first reports, for years ending 31 December 2025, shows how the relief is being used. It reviewed 40 of the 312 sustainability reports lodged, and according to ASIC, 82.5% of entities in that sample relied on the one-year Scope 3 relief. ASIC also says entities relying on it must "label any information about scope 3 greenhouse gas emissions disclosed elsewhere as voluntary information". Its report stresses "the need for faithful representation (as opposed to absolute precision)", which is useful context for a first Scope 3 estimate.

Is anything changing?

Not for Scope 3 in the near term, as at 13 November 2026. Treasury's August 2026 consultation paper says the Government "is not seeking views on changes to Scope 3 emissions reporting requirements". It also says its changes "will not impact those reporting for the 2026-27 financial year".

Submissions on Treasury's paper closed in early October 2026, and no government response had been published when we checked on 13 November 2026. Separately, the GHG Protocol is revising its Corporate Standard. Its development plan estimates a consolidated draft for public consultation in the second quarter of 2027 and a published revised standard in the fourth quarter of 2028. AASB S2 names the 2004 edition. So, as written, a revision changes nothing for an AASB S2 reporter unless the AASB changes that reference.

What should you do with these examples?

Use the Scope 1, 2 and 3 emissions examples as prompts, then build your own list. Map every emissions source the business has against all 15 Scope 3 categories, and record why each category is in or out. AASB S2 asks which categories are included, so that record is part of the disclosure work.

For a mid-sized Australian organisation preparing an AASB S2 disclosure without a dedicated sustainability team, Trace combines carbon accounting software with a specialist advisory team, and every output is reviewed by an expert. An organisation that needs bespoke financed-emissions or physical-asset modelling, such as a complex financial institution or an asset-heavy business, may be better served by a specialist in that work.

Frequently asked questions

What are scope 1, 2 and 3 emissions in Australia?

Under AASB S2, Scope 1 is direct emissions from sources an entity owns or controls. Scope 2 comes from the electricity, steam, heating or cooling it buys, and Scope 3 is the rest of its value chain. AASB S2 requires all three, while the separate National Greenhouse and Energy Reporting (NGER) scheme covers Scope 1 and 2 only.

What are examples of scope 2 emissions?

Scope 2 covers the electricity, steam, heating or cooling a business buys and uses, such as grid power for offices, stores or hotels. In ASIC's hotel example, two Sydney properties and one in Brisbane use 2.5 million kWh a year. On DCCEEW's 2026 location-based factors, that is 1,525 t CO2-e of Scope 2, by our calculation.

What is an example of scope 3 emissions?

ASIC gives several. Flights for employees to attend interstate meetings are business travel, category 6. Employees driving to the office are commuting, category 7. Landfill waste from office operations falls in category 5. Each happens outside the business but within its value chain, which is why it counts as Scope 3.

Does an office-based business have scope 1 emissions?

It can. The GHG Protocol's table for service sector and office-based organisations lists refrigerant leaks from air conditioning as a Scope 1 source, alongside fuel burned on site and in vehicles the business owns or controls. Whether a particular office has any depends on its equipment, its vehicles and whether it controls its premises.

When do Group 2 entities report scope 3 emissions?

From their second reporting year. Group 2's first year covers financial years starting 1 July 2026 to 30 June 2027, and AASB S2's transition relief means Scope 3 is not required then. Under ASSA 5010, Scope 3 then has limited assurance in years two and three and reasonable assurance from year four.

About the author

Trace is a climate reporting platform with in-house specialists, founded in 2020 with offices in Sydney and London. It helps Australian organisations measure emissions and prepare AASB S2 climate disclosures.

Reviewed by Joanna Auburn, Co-founder and Chief Product Officer of Trace.

Related reading

This article is general information about Australian climate reporting requirements as at the date shown. It is not legal, accounting or assurance advice.

Sources

All read at the primary source on 13 November 2026.

Standards and the standard setters

  • Australian Accounting Standards Board (AASB). "AASB S2 Climate-related Disclosures." September 2024. Paragraphs 29(a), B23, B32, C4 and C5, and Appendix A. AASB S2, September 2024 (PDF)
  • AASB. "AASB S2 Climate-related Disclosures", compiled version prepared 18 December 2025, applying to annual periods beginning on or after 1 January 2027. Paragraphs 29(a)(vi), 29A, B59, B62 and B63, and Basis for Conclusions BC28. AASB S2 compiled (PDF)
  • AASB. "Greenhouse Gas Emissions Disclosure requirements applying AASB S2: Educational material." August 2025. Pages 6 and 9. AASB educational material (PDF)
  • Auditing and Assurance Standards Board (AUASB). "ASSA 5010 Timeline for Audits and Reviews of Information in Sustainability Reports under the Corporations Act 2001." Compiled 24 December 2025, registered 15 January 2026 (F2026C00028). ASSA 5010 (PDF)
  • Greenhouse Gas Protocol. "A Corporate Accounting and Reporting Standard." Revised edition, 2004. Chapter 4, page 27, and Appendix D, page 93 (service sector and office-based organisations). GHG Protocol Corporate Standard (PDF)
  • Greenhouse Gas Protocol. "Corporate Value Chain (Scope 3) Accounting and Reporting Standard." 2011. Pages 38, 39, 46, 48 and 125. GHG Protocol Scope 3 Standard (PDF)
  • Greenhouse Gas Protocol. "Corporate Standard: Standard Development Plan." Consolidated 29 July 2026. GHG Protocol development plan (PDF)

Regulators and government

  • Australian Securities and Investments Commission (ASIC). "Sustainability reporting educational modules", Module 6, Units 2, 3 and 4. ASIC states these are not regulatory guidance. Unit 2 (PDF), Unit 3 (PDF), Unit 4 (PDF)
  • ASIC. "Report 839." 21 September 2026. ASIC Report 839 (PDF)
  • ASIC. "Sustainability reporting for small business." ASIC small business page
  • Clean Energy Regulator. "Emissions and energy types." Last updated 28 February 2025. Clean Energy Regulator page
  • DCCEEW 2026, Australian National Greenhouse Accounts Factors, Department of Climate Change, Energy, the Environment and Water, Canberra, August. CC BY 4.0. Section 1.1, section 3.1 and Tables 1, 9 and 10. NGA Factors 2026 (PDF)
  • The Treasury. "Improving the efficiency of climate-related financial disclosures." Consultation paper, August 2026. Treasury consultation paper (PDF), and the consultation page. No government response was published when checked.

Other sources

  • CDP. "Technical Note: Relevance of Scope 3 Categories by Sector." Version 3.0, 28 June 2024. Pages 4, 6, 7, 32, 50 and 51. Global 2021 response data. The 85% real estate figure is the UK Green Building Council's (2019), as cited by CDP. CDP technical note (PDF)
Free ASRS resources
for mandatory reporters.
ASRS Strategy On A Page

A one-page visual of the four AASB S2 pillars, what each requires, key deadlines, and the step-by-step compliance path. Start here if your team is scoping what ASRS S2 actually involves.

Download
The ASRS Pulse Report 2025

Benchmark your readiness against 20+ ASRS compliant Australian companies. Includes buying criteria, support gaps, and how first-round filers are approaching year one.

Download
The ASRS Prep Pack 2026

Templates, checklists and frameworks to start your AASB S2 implementation. Built for finance and sustainability leads who are ready to move.

Download
AASB Readiness Assessment

A 5-minute self-assessment. Get a compliance gap map and personalised next steps, scored against the four AASB S2 pillars.

Download

Related reading

Minimum Viable Compliance: What ASRS Year One Actually Requires
Read More
The Real Cost of Delaying ASRS Preparation
Read More
What Finance Leaders Told Us About Mandatory Climate Reporting
Read More
ASRS S2 and AASB: The Full Explainer
Read More

Ready to simplify your climate disclosure?

Trace works with businesses at every stage of their mandatory reporting journey, from first emissions measurement to audit-ready ASRS S2 disclosure. Talk to our team to see how we can help.

Newsletter:  Climate Reporting Simplified.
This monthly edition unpacks what mandatory climate reporting really requires and how to minimise cost, disruption & confusion.

💚 Don’t worry, we won’t spam!

London - Sydney

© Copyright 2026 Trace | All Rights Reserved